Component Solution Services REC02F Manual de Serviço Página 85

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 84
Ultraview 1030/1050 Monitors — Service Manual
4-21
Maintenance
3 Remove the six jackscrews and the knurled nuts (two each) not shown. The knurled nuts are
located on the audio jacks and require a special tool for removal (P/N 003-0117-xx).
Figure 4-14: Removing the I/O bay PCBA
4 Remove the three 6-32 × 1/4 inch screws holding the I/O bay PCBA.
Removing the Gas Interface PCBA for Option G
Figure 4-15: PCBA support plate and gas interface PCBA for option G
1 Remove four each 6-32 × 1/4 inch screws holding the support plate to access the gas interface
PCBA assembly.
2 Remove the label directly over the assembly on the outside of the case.
Vista de página 84
1 2 ... 80 81 82 83 84 85 86 87 88 89 90 ... 141 142

Comentários a estes Manuais

Sem comentários